  • Quiet system minimizes monitor noise
  • Breath-by-breath CO2 detection
  • Disappearing display and no audible alarms or pulse tones in sleep mode
  • Incorporates economical sidestream technology
  • Optional remote alarms
  • Internal rechargeable battery
  • Systems include monitor, moisture traps, moisture trap adaptor, sample lines, AC power cord, operation manual, service manual (CD)
  • Display, indicators, displayed trends, displayed, waveforms
  • Alarms - Physiological: Adjustable volume user-selectable high and low limits for all displayed parameters screen indicators for each parameter; system adjustable volume; silence: Temporary 2 min or off LED indicator
  • 150 mL/min, ±20 Flow rate
  • CO2 - Non-dispersive IR absorption measurement; 0 to 10% CO2 STPD (standard temperature and pressure dry) unit measurement range; user-selectable mmHg, vol. %, kPa; 0 to 100 mmHg or 0 to 10% CO2 or 0 to 13.3 kPa display range; ±2 mmHg accuracy; ±0.3%; ±0.3 kPa, or 4% of reading, whichever is greater (0 to 10% CO2 ); 1 mmHg resolution; 0.1%; 0.1 kPa; calibration 2 point cal; N2O compensation user-selectable 40% (default=off); rise time 360 minutes (average); : 4 Breath averaging, or breath-to-breath selectable
  • Respiration time - 0 to 150 bpm range; 4 Breath average; ±1 bpm accuracy
  • SpO2 - 0 to 100% SpO2 (functional) range; ±2% at 70 to 100%, <70% unspecified accuracy; 2, 4, 8, or 16-beat averaging (default: 2)
  • Pulse rate - 30 to 254 bpm; greater of ± 2 bpm or ±2% accuracy; 8 sec averaging; pulse tone pitch corresponds SpO2 value, volume adjustable or off
  • 105 to 125 V AC, 60 Hz; 90 to 110 V AC, 50 Hz; 208 to 252 V AC, 50 to 60 Hz power requirements
  • Nickel cadmium battery, 6 V DC, internal rechargeable, not user replaceable, fully- charged continuous life of approximately 2 hours, maximum full charge time 4 hours battery life
  • Analog output - CO2 waveform, plethysmogram, end tidal CO2, respiration rate, inspired CO2, %SpO2, pulse rate, 0 or 1 V cal signal any four; 0 to 1 VDC full scale range
  • Serial output: Tabular trends, patient data RS232C; 10 Hours at 4 sec, 31 hours at 12 sec sleep study

  • Item Id 770602