Covidien Pulse Co-Oximeter Nellcor Battery Operated Audible and Visible Alarm - M-1073254-2250 | Each

Packaging *

Covidien

Pulse Co-Oximeter

In Stock

M-1073254-2250

-
+

Delivery - 1-2 Weeks, Directly Ships from the Manufacturer

  • Incorporates the latest Nellcor™ digital signal processing technology for accurate, reliable readings even during low perfusion, motion and other forms of signal interference
  • Provides clinicians with real‑time information regarding their patients’ respiratory status, including continuous SpO2 and pulse rate monitoring and trending data
  • Includes SatSeconds alarm management, a clinician‑controlled feature that can distinguish between real, clinically significant events and transient events by taking into account both the severity and the duration of any desaturation event
  • Meets IEC 60601-1-11 standards for home health equipment compliant homecare and sleep study modes for safe and effective use of the monitor by lay users and in non‑hospital settings
  • 1% to 100% SpO2, 20 to 250 beats per minute (bpm) pulse rate; 0.03% to 20% pulse amplitude measurement range
  • Saturation - adult: 70% to 100% ± 2 digits; adult and neonate low sat: 60% to 80% ± 3 digits; neonate: 70% to 100% ± 2 digits; low perfusion: 70% to 100% ± 2 digits; adult and neonate with motion: 70% to 100% ± 4 digits
  • Pulse rate - adult and neonate: 20 to 250 bpm ± 3 digits; low perfusion: 20 to 250 bpm ± 3 digits; adult and neonate with motion: 20 to 250 bpm ± 5 digits
  • Power requirements: 100 to 240 V AC, 50/60 Hz, 45 VA; Fast-acting 2 A 32 V AC/DC, fast-acting 500 mA 32 V AC/50 DC fuse rating; lithium ion battery; minimum of five hours using new, fully charged battery with no alarms; optional 10-hour battery capacity
  • Operating temperature - Instrument: 5 to 40 °C; Transport/storage temperature: 20 to 60 °C
  • Operating humidity - 15% to 93% noncondensing
  • -170 to 4877 Meter Operating altitude
  • 82 X 155 X 255 mm Size
  • Accuracy - Accurately assesses patients’ status with pulse oximetry measurements of ± 2 for 70% to 100% saturation, and low saturation accuracy of ± 3 for 60% to 80%
  • Speed - reacts to patient status with technology that displays patient oxygenation and pulse rate more quickly than other technologies
  • Motion tolerance - Accurately assesses patients’ status during periods of movement or noise, avoiding dropouts or delays, Covidien is the first company to receive FDA clearance for a motion tolerant pulse oximeter that is also compliant with ISO 80601-2-61
  • Displays real time SpO2 and pulse rate measurements, plethysmographic waveforms and pulse amplitude
  • SatSeconds alarm management
  • Sleep Study mode

  • Item Id 1073254
    MF ID PM100N-HC
    Brand Nellcor™
    Manufacturer Covidien
    Alarm Type Audible and Visible Alarm
    Application Pulse Co-Oximeter
    UNSPSC Code 42181805