Siemens Reagent Atellica IM Diluent Human Chorionic Gonadotr...
Delivery - 7-10 Days, Ship Directly from Manufacturer Item Id 1123768 MF ID 10995691 Brand Atellica® IM Manufacturer Siemens Application Reagent Form Liquid Product Dating McKesson Acceptable Dating: we will ship >= 90 days Test Name Hu...
Siemens Reagent Atellica IM General Chemistry Vitamin B12 Fo...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Vitamin B12 (VB12) assay is for in vitro diagnostic use in the quantitative determination of vitamin B12 in human serum and plasma (EDTA and heparin) using the Atellica™ IM Analyzer WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov It...
Siemens Reagent Atellica IM Hepatitis / Antibody Test HAV Ig...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerAtellica™ IM Hepatitis A IgM (aHAVM) assay is for in vitro diagnostic use in the qualitative determination of IgM response to the hepatitis A virus (HAV) in human pediatric (aged 2–21 years) and adult serum and plasma (EDTA, lithium heparin, and sodium heparin) This ass...
Siemens Reagent Atellica IM Hepatitis / Antibody Test Hepati...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica® IM Anti-Hepatitis B surface Antigen 2 (aHBs2) assay is an in vitro diagnostic immunoassay for the qualitative and quantitative determination of total antibodies to hepatitis B surface antigen in human adult, adolescent, and pediatric serum or plasma The as...
Siemens Reagent Atellica IM Hepatitis / Serological Assay He...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Hepatitis A Total (HAVT) assay is for in vitro diagnostic use in the qualitative determination of total antibodies to hepatitis A virus (anti-HAV) in human neonatal, pediatric, and adult serum and plasma (EDTA, lithium heparin, and sodium heparin) This ...
Siemens Reagent Atellica IM Hepatitis / Serological Assay He...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica® IM Hepatitis B surface Antigen II Confirmatory (HBsII Conf) assay is an in vitro immunoassay for the qualitative confirmation of hepatitis B surface antigen (HBsAg) in human serum and plasma (potassium EDTA, lithium heparin, and sodium heparin), and with n...
Siemens Reagent Atellica IM Hepatitis / Serological Assay He...
Delivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica® IM Hepatitis B surface Antigen II (HBsII) assay is an in vitro immunoassay for the qualitative detection of hepatitis B surface antigen (HBsAg) in human adult, adolescent, and pediatric serum and plasma The assay may be used in conjunction with other serological and clinical info...
Siemens Reagent Atellica IM Immunochemistry / Specific Prote...
Delivery - 7-10 Days, Ship Directly from Manufacturer Item Id 1109484 MF ID 10995616 Brand Atellica® IM Manufacturer Siemens Application Reagent For Use With For Atellica® IM Analyzer Form Liquid Test Name Total Immunoglobulin E (tIgE) Dil...
Siemens Reagent Atellica IM Immunochemistry / Specific Prote...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Total IgE (tIgE) assay is for in vitro diagnostic use in the quantitative determination of total IgE in human serum using the Atellica™ IM Analyzer Immunoglobulin E (IgE) is a trace protein in serum and normally accounts for less than 0.001% of total se...
Siemens Reagent Atellica IM Immunochemistry / Specific Prote...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Total IgE (tIgE) assay is for in vitro diagnostic use in the quantitative determination of total IgE in human serum using the Atellica™ IM Analyzer Immunoglobulin E (IgE) is a trace protein in serum and normally accounts for less than 0.001% of total se...
Siemens Reagent Atellica IM Immunology / Serology Test Syphi...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Syphilis (Syph) assay is for in vitro diagnostic use in the qualitative determination of antibodies to Treponema pallidum in human serum and plasma (EDTA, lithium heparin, sodium heparin, and citrate) as an aid in the diagnosis of syphilis Item Id...
Siemens Reagent Atellica IM Immunology / Serology Test Toxop...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Toxoplasma IgG (Toxo G) assay is an IgG-antibody capture microparticle direct in vitro diagnostic immunoassay intended for the quantitative and qualitative detection of IgG antibodies to Toxoplasma gondii in human serum and plasma Item Id 11089...
Siemens Reagent Atellica IM Immunology / Serology Test Toxop...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Toxoplasma IgM (Toxo M) assay is an IgM antibody capture microparticle direct chemiluminescent in vitro diagnostic immunoassay intended for the qualitative detection of IgM antibodies to Toxoplasma gondii in human serum and plasma The Atellica IM Toxo M...
Siemens Reagent Atellica IM Infectious Disease Immunoassay R...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Rubella IgG (Rub G) assay is an IgG-antibody capture microparticle direct chemiluminescent in vitro diagnostic immunoassay for the quantitative and qualitative detection of IgG antibodies to the rubella virus in human serum and plasma This assay is used...
Siemens Reagent Atellica IM Infectious Disease Immunoassay R...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Rubella IgM (Rub M) assay is an IgM antibody capture microparticle direct chemiluminescent in vitro diagnostic immunoassay for the qualitative detection of IgM antibodies to the rubella virus in human serum and plasma (EDTA and heparin) This assay is us...
Siemens Reagent Atellica IM Metabolic Immunoassay Homocystei...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Homocysteine (HCY) assay is for in vitro diagnostic use in the quantitative determination of total homocysteine in human serum and plasma (EDTA and lithium heparin) using the Atellica™ IM Analyzer Item Id 1109049 MF ID 10995606 ...
Siemens Reagent Atellica IM Nutritional Assessment / Anemia ...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Ferritin (Fer) assay is for in vitro diagnostic use in the quantitative determination of ferritin in human serum and plasma (EDTA and lithium heparin) using the Atellica™ IM Analyzer This assay can be used as an aid in the diagnosis of iron deficiency a...
Siemens Reagent Atellica IM Nutritional Assessment / Anemia ...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Ferritin (Fer) assay is for in vitro diagnostic use in the quantitative determination of ferritin in human serum and plasma (EDTA and lithium heparin) using the Atellica™ IM Analyzer This assay can be used as an aid in the diagnosis of iron deficiency a...
Siemens Reagent Atellica IM Pre-treatment Reagent BR 27.29 F...
Delivery - 7-10 Days, Ship Directly from Manufacturer Item Id 1109495 MF ID 10995480 Brand Atellica® IM Manufacturer Siemens Application Reagent For Use With For Atellica® IM Analyzer Form Liquid Test Name Pre-treatment Reagent BR 27.29 ...
Siemens Reagent Atellica IM Reproductice Hormone Assay Sex H...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica® IM Sex Hormone Binding Globulin (SHBG) assay is for in vitro diagnostic use in the quantitative determination of sex-hormone-binding globulin (SHBG) in human serum and plasma (lithium heparin) using the Atellica® IM Analyzer The Atellica IM SHBG assay is i...
Siemens Reagent Atellica IM Reproductive Endocrinology Assay...
Delivery - 7-10 Days, Ship Directly from ManufacturerWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Item Id 1109483 MF ID 10995563 Brand Atellica® IM Manufacturer Siemens Application Reagent For Use With For Atellica® IM Analyzer Form Liqu...
Siemens Reagent Atellica IM Reproductive Endocrinology Assay...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Enhanced Estradiol (eE2) assay is for in vitro diagnostic use in the quantitative determination of estradiol in human serum and plasma (EDTA and heparin) using the Atellica™ IM Analyzer WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ...
Siemens Reagent Atellica IM Reproductive Endocrinology Assay...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Enhanced Estradiol (eE2) assay is for in vitro diagnostic use in the quantitative determination of estradiol in human serum and plasma (EDTA and heparin) using the Atellica™ IM Analyzer WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ...
Siemens Reagent Atellica IM Reproductive Endocrinology Assay...
Item is Non - ReturnableDelivery - 7-10 Days, Ship Directly from ManufacturerThe Atellica™ IM Follicle Stimulating Hormone (FSH) assay is for in vitro diagnostic use in the quantitative determination of follicle-stimulating hormone (FSH) in human serum using the Atellica™ IM Analyzer WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov...