Soma Technology Refurbished EKG Machine GE MAC 1200 12 Leads - Simultaneously Acquisition M-1013021-7979 | Each

Title *

Soma Technology

Cardio-Pulmonary Software

In Stock

M-1013021-7979

-
+

Refurbished EKG Machine GE MAC 1200 12 Leads - Simultaneously Acquisition, Type CF according to IEC Signal Input, 1000 Samples/Sec/Channel Digital Sampling Rate, Differential Signals for AC Voltage ±, 10 mV Superimposed DC Voltage (Polarization Voltage) ±600 mV Dynamic Range, 5 uV Resolution, 0.04 to 150 Hz Frequency Response, > 140 dB Common Mode Rejection, > 100 M ohms Input Impedance, < 10 uA Leakage Current, All leads, Duration 0.1 to 2.5 ms, Amplitude > 5 mV Pacemaker Detection Sensitivity, 10 to 120 V (0.32 A)/220 to 240 V (0.16 A), 49 to 65 Hz, NiCad, 18 V, 1.4 Ah, 4 hr, 3.7 X 12.6 X 14.5 Inch
MACHINE, EKG GE MARQUETTE MAC 1200 6CHANNEL 12LEAD

Item No.  1013021
MF ID SSA-040716-0941
Brand GE Mac 1200
Manufacturer Soma Technology
Application Refurbished EKG Machine
Specifications 12 Leads - Simultaneously Acquisition, Type CF according to IEC Signal Input, 1000 Samples/Sec/Channel Digital Sampling Rate, Differential Signals for AC Voltage ±, 10 mV Superimposed DC Voltage (Polarization Voltage) ±600 mV Dynamic Range, 5 uV Resolution, 0.04 to 150 Hz Frequency Response, > 140 dB Common Mode Rejection, > 100 M ohms Input Impedance, < 10 uA Leakage Current, All leads, Duration 0.1 to 2.5 ms, Amplitude > 5 mV Pacemaker Detection Sensitivity, 10 to 120 V (0.32 A)/220 to 240 V (0.16 A), 49 to 65 Hz, NiCad, 18 V, 1.4 Ah, 4 hr, 3.7 X 12.6 X 14.5 Inch
UNSPSC Code 42181701

Features

  • Refurbished in an ISO 13485 Certified FDA registered Facility
  • This system can be configured to meet the needs of hospitals, clinics and office-based practices
  • Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
  • Comprehensive solution for EKG requirements
  • Waveform LCD Display
  • Interpretive EKG
  • Full-size paper reports
  • Portable with built-in battery
  • Measurements, interpretation and memory available in any combination
  • Simultaneous 12-lead ECG acquisition and analysis
  • Compact, lightweight design with carrying handle
  • Field upgradability
  • Anti drift system (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes
  • Baseline adjustment: ECG presentation on averaged baseline
  • Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break; each single electrode is monitored
  • Copy: In the automatic 12 lead mode , after ECG, recording, copies of the ECG can be printed
  • Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input