Refurbished EKG Machine GE MAC 1200 12 Leads - Simultaneously Acquisition, Type CF according to IEC Signal Input, 1000 Samples/Sec/Channel Digital Sampling Rate, Differential Signals for AC Voltage ±, 10 mV Superimposed DC Voltage (Polarization Voltage) ±600 mV Dynamic Range, 5 uV Resolution, 0.04 to 150 Hz Frequency Response, > 140 dB Common Mode Rejection, > 100 M ohms Input Impedance, < 10 uA Leakage Current, All leads, Duration 0.1 to 2.5 ms, Amplitude > 5 mV Pacemaker Detection Sensitivity, 10 to 120 V (0.32 A)/220 to 240 V (0.16 A), 49 to 65 Hz, NiCad, 18 V, 1.4 Ah, 4 hr, 3.7 X 12.6 X 14.5 Inch
MACHINE, EKG GE MARQUETTE MAC 1200 6CHANNEL 12LEAD
Item No. | 1013021 |
MF ID | SSA-040716-0941 |
Brand | GE Mac 1200 |
Manufacturer | Soma Technology |
Application | Refurbished EKG Machine |
Specifications | 12 Leads - Simultaneously Acquisition, Type CF according to IEC Signal Input, 1000 Samples/Sec/Channel Digital Sampling Rate, Differential Signals for AC Voltage ±, 10 mV Superimposed DC Voltage (Polarization Voltage) ±600 mV Dynamic Range, 5 uV Resolution, 0.04 to 150 Hz Frequency Response, > 140 dB Common Mode Rejection, > 100 M ohms Input Impedance, < 10 uA Leakage Current, All leads, Duration 0.1 to 2.5 ms, Amplitude > 5 mV Pacemaker Detection Sensitivity, 10 to 120 V (0.32 A)/220 to 240 V (0.16 A), 49 to 65 Hz, NiCad, 18 V, 1.4 Ah, 4 hr, 3.7 X 12.6 X 14.5 Inch |
UNSPSC Code | 42181701 |
Features
- Refurbished in an ISO 13485 Certified FDA registered Facility
- This system can be configured to meet the needs of hospitals, clinics and office-based practices
- Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
- Comprehensive solution for EKG requirements
- Waveform LCD Display
- Interpretive EKG
- Full-size paper reports
- Portable with built-in battery
- Measurements, interpretation and memory available in any combination
- Simultaneous 12-lead ECG acquisition and analysis
- Compact, lightweight design with carrying handle
- Field upgradability
- Anti drift system (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes
- Baseline adjustment: ECG presentation on averaged baseline
- Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break; each single electrode is monitored
- Copy: In the automatic 12 lead mode , after ECG, recording, copies of the ECG can be printed
- Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input