{"product_id":"ortho-clinical-diagnostics-calibrator-vitros-r-anti-sars-cov-2-total-2-x-1-ml-for-use-with-anti-sars-cov-2-total-reagent-pack-test-on-vitros-eci-eciq-available-end-of-may-2020-vitros-3600-5600-xt7600-ready-to-use-m-1165645-2214-each","title":"Ortho Clinical Diagnostics Calibrator Vitros® Anti-SARS-CoV-2 Total 2 X 1 mL For use with Anti-SARS-CoV-2 Total Reagent Pack Test on Vitros ECi \/ ECiQ (Available End of May 2020) \/ Vitros 3600 \/ 5600 \/ XT7600 Ready-to-Use - M-1165645-2214 - Each","description":"\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eItem is Non - Returnable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff0000;\"\u003eDelivery - 7-10 Days, Ship Directly from Manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\u003cli\u003eFor use under the Food and Drug Administration's Emergency Use Authorization only: https:\/\/www.fda.gov\/medical-devices\/emergency-situations-medical-devices\/emergency-use-authorizations\u003c\/li\u003e \u003cli\u003eTesting is limited to laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. section 263a, to perform moderate and high complexity tests\u003c\/li\u003e \u003cli\u003eVITROS Immunodiagnostic Products Anti-SARS-CoV-2 Total test is performed using the VITROS Anti-SARS-CoV-2 Total Reagent Pack and the VITROS Anti-SARS-CoV-2 Total Calibrator on the VITROS ECi\/ECiQ\/3600 Immunodiagnostic System and the VITROS 5600\/XT 7600 Integrated Systems\u003c\/li\u003e \u003cli\u003eResults are for the detection of total SARS-CoV-2 antibodies; reactive results could occur after infection and can be indicative of acute or recent infection\u003c\/li\u003e \u003cli\u003eLaboratories within the United States and its territories are required to report all reactive results to the appropriate public health authorities\u003c\/li\u003e \u003cli\u003eNon-reactive results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions; results must be combined with clinical observations, patient history, and epidemiological information\u003c\/li\u003e \u003cli\u003eRx ONLY; For in vitro diagnostic and Laboratory Professional use; For emergency authorization use ONLY\u003c\/li\u003e \u003cli\u003eCalibrator contains: SARS-CoV-2 antibody negative plasma obtained from donors who were tested individually and who were found to be negative for hepatitis B surface antigen, and for antibodies to hepatitis C virus (HCV) and HIV, using approved methods (enzyme immunoassays)\u003c\/li\u003e \u003cli\u003eCalibrator contents: 2 vials of VITROS Anti‑SARS-CoV-2 Total Calibrator (anti-SARS-CoV-2 in anti-SARS-CoV-2 negative human plasma with antimicrobial agent, 1 mL)\u003c\/li\u003e \u003cli\u003eThe VITROS Anti‑SARS-CoV-2 Total test uses 80 μL of calibrator for each determination\u003c\/li\u003e\u003cbr\u003e \u003ctable class=\"tblSimple\" summary=\"Product Attributes\"\u003e\u003ctbody\u003e  \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003eItem Id\u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e1165645\u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003eMF ID\u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e6199923\u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003eBrand\u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003eVitros®\u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003eManufacturer\u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003eOrtho Clinical Diagnostics\u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Application \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e Calibrator \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Container Type \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e Vial \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e For Use With \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e For use with Anti-SARS-CoV-2 Total Reagent Pack Test on Vitros ECi \/ ECiQ (Available End of May 2020) \/ Vitros 3600 \/ 5600 \/ XT7600 \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Form \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e Ready-To-Use \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Product Dating \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e McKesson Acceptable Dating: we will ship \u0026gt;= 90 days \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Storage Requirements \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e Requires Refrigeration \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Test Name \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e Anti-SARS-CoV-2 Total \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Test Type \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e Antibody Test \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e UNSPSC Code \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e 41116128 \u003c\/td\u003e   \u003c\/tr\u003e   \u003ctr\u003e    \u003ctd class=\"attrTitle\"\u003e Volume \u003c\/td\u003e    \u003ctd class=\"attrDat\"\u003e 2 X 1 mL \u003c\/td\u003e   \u003c\/tr\u003e  \u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ortho Clinical Diagnostics","offers":[{"title":"Each","offer_id":39988307427517,"sku":"M-1165645-2214","price":191.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/axiommedicals.com\/products\/ortho-clinical-diagnostics-calibrator-vitros-r-anti-sars-cov-2-total-2-x-1-ml-for-use-with-anti-sars-cov-2-total-reagent-pack-test-on-vitros-eci-eciq-available-end-of-may-2020-vitros-3600-5600-xt7600-ready-to-use-m-1165645-2214-each","provider":"Axiom Medical Supplies","version":"1.0","type":"link"}